Revolutionize your vacuum gauge experience with us!
The gauge heads PSG010, PSG017 and PSG018 are long-established passive Pirani gauges intended to operate with the Vacuum Gauge Controller VGC094. They are designed for vacuum measurement of gases in the pressure range of 8×10-4 to 1000 mbar. The compact metal design provides a robust solution suitable for general vacuum applications.
While PSG010 is suited for general vacuum applications, PSG017 and PSG018 respond to needs of demanding applications requiring bake-out temperature up to 250 °C or high ionizing radiation resistance, thanks to a metal sealing design. PSG017 has a Nickel filament suitable for corrosive media applications.
Advantages
- Elastomer (PSG010) or metal-sealed (PSG017, PSG018) design
- Specified high measurement accuracy and repeatability
- Bake-out temperature up to 100 °C (PSG010) / 250 °C (PSG017, PSG018)
- Ionizing radiation resistant up to 106 Gy (PSG017, PSG018)
- Corrosion resistance with Ni filament (PSG017)
- Cable length up to 100 m (500 m with PI 300 DL/CP 300 T11L)
Typical applications
- General vacuum measurement and control for demanding and/or high temperature applications from low to the high vacuum range
Operating Units
- Vacuum Gauge Controller VGC094
Specifications
Measurement principle | Pirani |
Measurement range (air, O2, CO, N2) | 8×10-4 … 1000 mbar |
Accuracy (N2) | |
in the range of ≥100 mbar | up to factor 2 of reading |
at room temperature and cable length <20 m | ~±20% of reading in the range of 1×10-1 ... 10 mbar up to factor 2 of reading in the range of ≤10-2 mbar |
Repeatability (N2) | ~±2% of reading in the range of 1×10-2 ... 100 mbar |
Feedthrough | Internal seal | Glass | Elastomer (FPM) |
Bake-out temperature | ≤100 °C |
Max operating distance | ≤100 m |
Materials exposed to vacuum | AIMgSi, glass, FPM, W, Ni, sinter bronze |
Features | Tungsten (W) filament |
Measurement principle | Pirani |
Measurement range (air, O2, CO, N2) | 8×10-4 … 1000 mbar |
Accuracy (N2) | |
in the range of ≥100 mbar | up to factor 2 of reading |
at room temperature and cable length <20 m | ~±10% of reading in the range of 1×10-2 ... 100 mbar |
Repeatability (N2) | ~±2% of reading in the range of 1×10-2 ... 100 mbar |
Feedthrough | Internal seal | AI2O3 ceramic | Metal |
Bake-out temperature | ≤250 °C |
Max operating distance | ≤100 m |
Ionizing radiation tolerance | 106 Gy |
Materials exposed to vacuum | Stainless steel, AI2O3, Ag, Ni |
Features | Nickel (Ni) filament, corrosion resistant |
Measurement principle | Pirani |
Measurement range (air, O2, CO, N2) | 8×10-4 … 1000 mbar |
Accuracy (N2) | |
in the range of ≥100 mbar | up to factor 2 of reading |
at room temperature and cable length <20 m | ~±10% of reading in the range of 1×10-2 ... 100 mbar |
up to +70 °C and within the entire range of specified cable length | ~±20% of reading in the range of 1×10-2 ... 100 mbar |
within the entire specified range of temperatures and cable length | ~±35% of reading in the range of 1×10-2 ... 100 mbar |
Repeatability (N2) | ~±2% of reading in the range of 1×10-2 ... 100 mbar |
Feedthrough | Internal seal | AI2O3 ceramic | Metal |
Bake-out temperature | ≤250 °C |
Max operating distance | ≤500 m (with PI 300 DL/CP 300 T11L) |
Ionizing radiation tolerance | 106 Gy |
Materials exposed to vacuum | Stainless steel, AI2O3, Ag, W, Ni |
Features | Tungsten (W) filament |